Ampatop F black (plus)
Black wind seal for façades with open gaps
Double layer, highly tear-resistant black façade membrane for façades with open joints, consisting of monolithic TPU technology.
- Withstands UV
- 10-year product guarantee with a joint width up to 50 mm / 40 %
- Tested with 5000 hours UV exposure
- Monolithic TPU technology
Double layer, highly tear-resistant black façade membrane for façades with open joints. According to EN13859-2 for walls with open joints, artificial ageing is carried out with 5000 hours of UV exposure (standard is 336 hours). Monolithic TPU technology
Article number | Description | Roll dimensions |
---|---|---|
7640115533500 | Ampatop F black | 1,5 m × 50 m = 75 m2 |
7640115536075 | Ampatop F black plus integrated tape | 1,5 m × 50 m = 75 m2 |
7640115533524 | Ampatop F black | 3,0 m × 30 m = 90 m2 |
Property | Value | Standard |
---|---|---|
Harmonised European Standard | EN 13859-2:2014 | |
Mass per unit area |
220 g/m2 |
EN 1849-2 |
Straightness |
< 30 mm/10 m |
EN 1848-2 |
Fire behaviour |
E | EN 13 501-1 / EN ISO 11925-2 |
Resistance to water penetration |
W1 | EN 1928 |
Water vapour permeability, sD value |
0,09 m | EN 1931 |
Width of overlap |
15 cm | |
Temperature resistance |
-40 to +80 °C | |
Maximum tensile strength longitudinal / transverse |
300 / 340 N/5 cm |
EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner |
Elongation longitudinal / transverse |
50 / 60 % |
EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner |
Resistance to tearing (nail) longitudinal / transverse |
200 / 185 N |
EN 12 310-1 without support liner EN 13 859-1, Appendix B, with support liner |
Dimensional Stability |
-2 % |
EN 1107-2 |
Cold bending behaviour (flexibility) |
-40 °C | EN 1109 |
Outdoor weathering |
3 months (before installation of façade cladding) | |
UV stability |
> 10 years | |
Gap width up to |
50 mm / 40 % | |
5'000-hour test | approved | EN 13859-2:2014 |
Visible defects | none | |
Values after artificial ageing | ||
Maximum tensile strength longitudinal / transverse |
300 / 340 N/5 cm |
EN 13859-1, appendix C, EN 1297, EN 1296 |
Elongation longitudinal / transverse |
300 / 340 N/5 cm |
EN 13859-1, appendix C, EN 1297, EN 1296 |
Resistance to water penetration |
W1 | EN 13859-1, appendix C, EN 1297, EN 1296 |
Technical data sheets
Technical data sheet: Ampatop F black (plus) | Technical data sheet: Ampatop F black (plus), black wind seal for façades with open gaps |
Declarations of performance
Declaration of performance: Ampatop F black | Declaration of performance: Ampatop F black 1,5 x 50 m, black wind seal for façades with open gaps | |
Declaration of perfomance: Ampatop F black | Declaration of perfomance: Ampatop F black 3,0 x 30 m, black wind seal for façades with open gaps | |
Declaration of perfomance: Ampatop F black plus | Declaration of perfomance: Ampatop F black plus 1,5 x 50 m, black wind seal for façades with open gaps |
Tendering texts
Tendering text: Ampatop F black (plus) | Tendering text: Ampatop F black (plus), black wind seal for façades with open gaps |
Product inserts
Product insert: Ampatop F black | Product insert: Ampatop F black 1,5 x 50 m, black wind seal for façades with open gaps | |
Product insert: Ampatop F black plus | Product insert: Ampatop F black plus 1,5 x 50 m, black wind seal for façades with open gaps, with integrated adhesive tape | |
Product insert: Ampatop F black | Product insert: Ampatop F black 3,0 x 30 m, black wind seal for façades with open gaps |
Certificates
Certificate: Ampatop F black | Certificate: Ampatop F black, 5'000 hours |
Product photos
Product photo: Ampatop F black plus | Product photo: Ampatop F black plus, black wind seal for façades with open gaps, with integrated tape | |
Product photo: Ampatop F black | Product photo: Ampatop F black, black wind seal for façades with open gaps |
Application photos
Application photo: Ampatop F black (plus) | Application photo: Ampatop F black (plus), black wind seal for façades with open gaps | |
Application photo: Ampatop F black (plus) | Application photo: Ampatop F black (plus), black wind seal for façades with open gaps |
Ampatop F black (plus) can be laid horizontally or vertically with the coated black side facing outwards. The laying direction must not be different on each side of the building.
Roll out the membrane, line it up, cut it to length, pull it tight and fix it in place, e.g. using stainless steel tacks (this should be invisible inside the overlap, which must be at least 10 cm). Always mount the final mechanical fixation after laying (e.g. counter battens)! Ampacoll ND Pads (nail seals) or Ampacoll ND.Band (nail sealing tape) should be used for this.
The integrated tape, Ampacoll Profix liquid adhesive or Ampacoll UV/ Ampacoll UV flexx acylic tape should be used for the wind and waterproof bonding of the overlap. This best-practice method also applies to necessary penetrations (e.g. for air vents, balcony mounts and cable holes) as well as window joints. Visible leakage of the adhesive must be avoided.
Ampacoll Profix is also used to bond Ampatop F black (plus) to metal furring within the insulation layer. The maximum distance horizontally or vertically is 1.45 m, and the minimum width of the profiles is 4 cm. The insulation must fill the entire cavity and be laid evenly and secured in place, so that the façade membrane is not negatively affected (no bulging, pushing out, etc.). When installing on wooden materials, pressure-resistant insulating materials or similar, it is recommended to bond using Ampacoll Profix every 70 cm horizontally and vertically, especially when only individual or sporadic brackets are installed for final fixing. The maximum distance between individual attachments is 70 cm (horizontal and vertical). N.B.: Protruding attachments must be split at insulation level and should not penetrate the membrane (e.g. two-piece brackets with clamping flanges).