Ampatop RF Color plus
Coloured wind seal for façades with open gaps, fire behaviour B
Two-layer, highly tear-resistant façade membranes with a coloured, monolithic TPU coating for all curtain-type ventilated façades.
- The fleece is made using recycled PET bottles (100 %): Protects the environment
- Long-term UV protection and age-resistant
- Fire behaviour: B-s1,d0
- Special colours available on request for quantities of at least 500 m²
- With a maximum percentage of opening of up to 80 mm / 50 %
Two-layer, highly tear-resistant façade membranes with a coloured, monolithic TPU coating for all curtain-type ventilated façades. Ampatop RF Color plus façade membranes are suitable for partially open façade surfacing in wood, expanded metal or perforated plate.
Article number | Description | Roll dimensions |
---|---|---|
7640442091414 | Ampatop RF Color plus black | 1,5 m × 50 m = 75 m2 |
7640442091612 | Ampatop RF Color plus white | 1,5 m × 50 m = 75 m2 |
7640442091636 | Ampatop RF Color plus red | 1,5 m × 50 m = 75 m2 |
Property | Value | Standard |
---|---|---|
Harmonised European Standard | EN 13859-2:2014 | |
Mass per unit area |
230 g/m2 |
EN 1849-2 |
Straightness |
< 30 mm/10 m |
EN 1848-2 |
Fire behaviour |
B-s1,d0 | EN 13 501-1 / EN ISO 11925-2 |
Resistance to water penetration |
W1 | EN 1928, procedure A |
Water vapour permeability, sD value |
0,4 m | EN 1931 |
Temperature resistance |
-40 to +80 °C | |
Maximum tensile strength longitudinal / transverse |
370 / 370 N/5 cm |
EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner |
Elongation longitudinal / transverse |
30 / 30 % |
EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner |
Resistance to tearing (nail) longitudinal / transverse |
180 / 180 N |
EN 12 310-1 without support liner EN 13 859-1, Appendix B, with support liner |
Dimensional Stability |
-2 % |
EN 1107-2 |
Cold bending behaviour (flexibility) |
-20 °C | EN 1109 |
Outdoor weathering |
3 months | |
UV stability |
> 10 years | |
Gap width up to |
80 mm / 50 % | |
Visible defects | none | |
Values after artificial ageing | ||
Maximum tensile strength longitudinal / transverse |
370 / 370 N/5 cm |
EN 13859-1, appendix C, EN 1297, EN 1296 |
Elongation longitudinal / transverse |
370 / 370 N/5 cm |
EN 13859-1, appendix C, EN 1297, EN 1296 |
Resistance to water penetration |
W1 | EN 13859-1, appendix C, EN 1297, EN 1296 |
Technical data sheets
Technical data sheet: Ampatop RF Color plus | Technical data sheet: Ampatop RF Color plus, coloured wind seal for façades with open gaps |
Product inserts
Product insert: Ampatop RF Color plus black 1,5 x 50 m | Product insert: Ampatop RF Color plus black 1,5 x 50 m, coloured wind seal for façades with open gaps, with integrated adhesive tape | |
Product insert: Ampatop RF Color plus red 1,5 x 50 m | Product insert: Ampatop RF Color plus red 1,5 x 50 m, coloured wind seal for façades with open gaps, with integrated adhesive tape | |
Product insert: Ampatop RF Color plus white 1,5 x 50 m | Product insert: Ampatop RF Color plus white 1,5 x 50 m, coloured wind seal for façades with open gaps, with integrated adhesive tape |
Product photos
Product photo: Ampatop RF Color plus red | Product photo: Ampatop RF Color plus red, coloured wind seal for façades with open gaps, with integrated adhesive tape | |
Product photo: Ampatop RF Color plus white | Product photo: Ampatop RF Color plus white, coloured wind seal for façades with open gaps, with integrated adhesive tape | |
Product photo: Ampatop RF Color plus black | Product photo: Ampatop RF Color plus black, coloured wind seal for façades with open gaps, with integrated adhesive tape |
Ampatop RF Color plus can be laid horizontally or vertically with the coloured side facing outwards. The laying direction must not be different on each side of the building.Roll out the membrane, line it up, cut it to length, pull it tight and fix it in place, e.g. using stainless steel tacks (this should be invisible inside the overlap, which must be at least 10 cm). Always mount the final mechanical fixation after laying (e.g. counter battens)! Ampacoll ND Pads (nail seals) or Ampacoll ND.Band (nail sealing tape) should be used for this.
Tape the overlaps down with the integrated adhesive tapes to make them rain-proof and wind-proof. Rub the adhesive locations in well. The liquid adhesive Ampacoll Profix is used to bond Ampatop RF Color plus to metal furring within the insulation layer. Ampacoll Profix should also be used for necessary penetrations (e.g. for air vents, balcony mounts and cable holes) as well as window joints. Visible leakage of the adhesive must be avoided. The maximum distance horizontally or vertically is 1.45 m, and the minimum width of the profiles is 4 cm. The insulation must fill the entire cavity and be laid evenly and secured in place, so that the façade membrane is not negatively affected (no bulging, pushing out, etc.). When installing on wooden materials, pressure-resistant insulating materials or similar, it is recommended to bond using Ampacoll Profix every 70 cm horizontally and vertically, especially when only individual or sporadic brackets are installed for final fixing. The maximum distance between individual attachments is 70 cm (horizontal and vertical). N.B.: Protruding attachments must be split at insulation level and should not penetrate the membrane (e.g. two-piece brackets with clamping flanges).