Ampatop Aero (plus)
Wall membrane
Triple layer, highly tear-resistant wall membrane.
- Diffusion-open yet wind-proof
- Cutting and orientation aid
- Ampatop Aero plus: integrated tapes on both sides
Triple layer, highly tear-resistant wall membrane. PP fleece with coating.
Article number | Description | Roll dimensions |
---|---|---|
7640115533821 | Ampatop Aero | 1,5 m × 50 m = 75 m2 |
7640115534798 | Ampatop Aero plus integrated tapes on both sides | 1,5 m × 50 m = 75 m2 |
7640115535542 | Ampatop Aero | 3,0 m × 50 m = 150 m2 |
7640115535566 | Ampatop Aero plus integrated tapes on both sides | 3,0 m × 50 m = 150 m2 |
Property | Value | Standard |
---|---|---|
Harmonised European Standard | EN 13859-2:2014 | |
Mass per unit area |
145 g/m2 |
EN 1849-2 |
Straightness |
< 30 mm/10 m |
EN 1848-2 |
Fire behaviour |
E | EN 13 501-1 / EN ISO 11925-2 |
Resistance to water penetration |
W1 | EN 1928 |
Water vapour permeability, sD value |
0,04 m | EN 1931 |
Width of overlap |
10 cm | |
Temperature resistance |
-40 to +80 °C | |
Maximum tensile strength longitudinal / transverse |
240 / 180 N/5 cm |
EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner |
Elongation longitudinal / transverse |
65 / 40 % |
EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner |
Resistance to tearing (nail) longitudinal / transverse |
145 / 185 N |
EN 12 310-1 without support liner EN 13 859-1, Appendix B, with support liner |
Cold bending behaviour (flexibility) |
-20 °C | EN 1109 |
approved | Driving rain test TU Berlin | |
Outdoor weathering |
3 months | |
Visible defects | none | EN 1850-2 |
Values after artificial ageing | ||
Maximum tensile strength longitudinal / transverse |
240 / 180 |
EN 13859-1, appendix C, EN 1297, EN 1296 |
Elongation longitudinal / transverse |
240 / 180 |
EN 13859-1, appendix C, EN 1297, EN 1296 |
Resistance to water penetration |
W1 | EN 13859-1, appendix C, EN 1297, EN 1296 |
Technical data sheets
Technical data sheet: Ampatop Aero (plus) | Technical data sheet: Ampatop Aero (plus), roof membrane |
Declarations of performance
Declaration of perfomance: Ampatop Aero 1,5 x 50 m | Declaration of perfomance: Ampatop Aero 1,5 x 50 m, roof and wall membrane | |
Declaration of perfomance: Ampatop Aero plus | Declaration of perfomance: Ampatop Aero plus 1,5 x 50 m, roof membrane, integrated tapes on both sides | |
Declaration of perfomance: Ampatop Aero | Declaration of perfomance: Ampatop Aero 3,0 x 50 m, roof membrane | |
Declaration of perfomance: Ampatop Aero plus | Declaration of perfomance: Ampatop Aero plus 3,0 x 50 m, roof, integrated tapes on both sides |
Product inserts
Product insert: Ampatop Aero | Product insert: Ampatop Aero 1,5 x 50 m, roof membrane | |
Product insert: Ampatop Aero plus | Product insert: Ampatop Aero plus 1,5 x 50 m, roof membrane, integrated tapes on both sides | |
Product insert: Ampatop Aero | Product insert: Ampatop Aero 3,0 x 30 m, roof membrane | |
Product insert: Ampatop Aero | Product insert: Ampatop Aero 3,0 x 50 m, roof membrane | |
Product insert: Ampatop Aero plus | Product insert: Ampatop Aero plus 3,0 x 50 m, roof membrane, integrated tapes on both sides |
Tendering texts
Tendering text: Ampatop Aero (plus) | Tendering text: Ampatop Aero (plus), roof and wall membrane, use as membrane for roof |
Product photos
Product photo: Ampatop Aero (plus) | Product photo: Ampatop Aero (plus), roof membrane |
Ampatop Aero (plus) should be laid onto the existing support structure or shell, parallel to the eaves, with an overlap of 10 cm. It should then be nailed (with broad-headed nails) or stapled in the overlapping section, with the overlap covering the nails or staples. Tape the overlaps down with the adhesive tape Ampacoll XT 60 mm or the integrated tapes to make them rain-proof and wind-proof. Rub the adhesive locations in well. Transverse joints should also overlap by 10 cm. These should be taped with Ampacoll Superfix or Ampacoll XT 60 mm. Fix cross battens with Ampacoll ND nail seals or Ampacoll ND.Band / ND Duo nail seal tape. Connections to gutter beds and the edges of chimneys, dormer windows and other built-in fitments must be permanently glued with Ampacoll Superfix and mechanically secured. Penetration points such as ventilation shafts, ventilation flues, etc must be sealed with Ampacoll BK 535 butyl rubber tape. Porous, dusty or fleecy sub-surfaces must be pretreated with Ampacoll® Primax or Airmax before applying Ampacoll BK butyl tapes.