Ampatop Secura (plus)
Roof membrane
Double layer, highly tear-resistant roof membrane.
- Diffusion-open yet wind-proof
- Cutting and orientation aid
- Monolithic TPU technology
- Ampatop Secura plus: integrated tape
Double layer, highly tear-resistant roof membrane. Monolithic TPU technology.
Conditions for the twenty-year premium warranty include registering the building object and the Ampack products used. In addition, our products must be used as part of a system. For further details, please see our General Warranty Conditions.
Article number | Description | Roll dimensions |
---|---|---|
7640115533920 | Ampatop Secura plus integrated tape | 1,5 m × 50 m = 75 m2 |
7640115535580 | Ampatop Secura | 3,0 m × 25 m = 75 m2 |
Property | Value | Standard |
---|---|---|
Harmonised European Standard | EN 13859-1:2014 | |
Mass per unit area |
220 g/m2 |
EN 1849-2 |
Straightness |
< 30 mm/10 m |
EN 1848-2 |
Fire behaviour |
E | EN 13 501-1 / EN ISO 11925-2 |
Resistance to water penetration |
W1 | EN 1928 |
Water vapour permeability, sD value |
0,15 m | EN 1931 |
Width of overlap |
10 cm | |
Temperature resistance |
-40 to +80 °C | |
Maximum tensile strength longitudinal / transverse |
300 / 350 N/5 cm |
EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner |
Elongation longitudinal / transverse |
50 / 50 % |
EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner |
Resistance to tearing (nail) longitudinal / transverse |
225 / 225 N |
EN 12 310-1 without support liner EN 13 859-1, Appendix B, with support liner |
Cold bending behaviour (flexibility) |
-20 °C | EN 1109 |
approved | Driving rain test TU Berlin | |
Outdoor weathering |
3 months | |
Minimum roof slope |
10° | |
Visible defects | none | EN 1850-2 |
Values after artificial ageing | ||
Maximum tensile strength longitudinal / transverse |
300 / 350 N/5cm |
EN 13859-1, appendix C, EN 1297, EN 1296 |
Elongation longitudinal / transverse |
300 / 350 N/5cm |
EN 13859-1, appendix C, EN 1297, EN 1296 |
Technical data sheets
Technical data sheet: Ampatop Secura (plus) | Technical data sheet: Ampatop Secura (plus), roof membrane |
Declarations of performance
Declaration of performance: Ampatop Secura | Declaration of performance: Ampatop Secura 1,5 x 50 m, roof membrane | |
Declaration of performance: Ampatop Secura plus | Declaration of performance: Ampatop Secura plus 1,5 x 50 m, roof membrane | |
Declaration of performance: Ampatop Secura | Declaration of performance: Ampatop Secura 3,0 x 25 m, roof membrane |
Product inserts
Product insert: Ampatop Secura | Product insert: Ampatop Secura 1,5 x 50 m, roof membrane | |
Product insert: Ampatop Secura plus | Product insert: Ampatop Secura plus 1,5 x 50 m, roof membrane, integrated tapes on both sides | |
Product insert: Ampatop Secura | Product insert: Ampatop Secura 3,0 x 25 m, roof membrane |
Product photos
Product photo: Ampatop Secura (plus) | Product photo: Ampatop Secura (plus), roof membrane |
Application photos
Application photo: Ampatop Secura (plus) | Application photo: Ampatop Secura (plus), roof membrane | |
Application photo: Ampatop Secura (plus) | Application photo: Ampatop Secura (plus), roof membrane |
Ampatop Secura (plus) should be laid onto the existing support structure or shell, parallel to the eaves, with an overlap of 10cm. It should then be nailed (with broad-headed nails) or stapled in the overlapping section, with the overlap covering the nails or staples. Tape the overlaps down with the adhesive tape Ampacoll XT 60 mm or the integrated tape to make them rain-proof and wind-proof. Rub the adhesive locations in well. Transverse joints should also overlap by 10 cm. These should be taped with Ampacoll Superfix (apply only to the fleecy reverse surface) or Ampacoll XT 60 mm. Fix cross battens with Ampacoll ND nail seals or Ampacoll ND.Band / ND Duo nail seal tape. Connections to gutter beds and the edges of chimneys, dormer windows and other built-in fitments must be permanently glued with Ampacoll Superfix (apply only to the fleecy reverse surface) and mechanically secured. Penetration points such as ventilation shafts, ventilation flues, etc must be sealed with Ampacoll BK 535 butyl rubber tape. Porous, dusty or fleecy sub-surfaces must be pretreated with Ampacoll Primax or Airmax before applying Ampacoll BK butyl tapes.