x
 » Ampatex SB 130 (plus)

Ampatex SB 130 (plus)

Formwork membrane and airtight layer

Product photo: Ampatex SB 130, formwork membrane and airtight layer
Application photo: Ampatex SB 130, formwork membrane and airtight layer
Application photo: Ampatex SB 130, formwork membrane and airtight layer
Application photo: Ampatex SB 130, formwork membrane and airtight layer

Double layer vapour check, airtight layer and formwork membrane.

  • Three months’ weather resistance
  • Translucent – the substructure remains visible
  • Very robust and suitable for harsh site conditions

Double layer weather-resistant vapour check, airtight layer and formwork membrane made of thermoset continuous polypropylene fibres with PP filler (100 % polypropylene). Weather-resistant. Ideal for rafter insulation.

Einsatzbereich

For internal and external pitched roofs, polished and unpolished timber frameworks, outside under the insulation.


20-year Ampack premium warranty

Conditions for the twenty-year premium warranty include registering the building object and the Ampack products used. In addition, our products must be used as part of a system. For further details, please see our General Warranty Conditions.

CE 13984:2013

ISO 9001

Article number Description Roll dimensions
7640442090790 Ampatex SB 130 plus
integrated tapes on both sides

1,5 m × 50 m = 75 m2

7640115535382

Ampatex SB 130

3,0 m × 50 m = 150 m2

Property Value Standard
Harmonised European Standard EN 13984:2013
Product description Typ A EN 13984:2013

Mass per unit area

135 g/m2

EN 1849-2

Straightness

< 75 mm/10 m

EN 1848-2

Fire behaviour

E EN 13 501-1 / EN ISO 11925-2
Waterproofing approved at 2 kPa EN 1928, procedure A

Water vapour permeability, sD value

40 m EN 1931

Width of overlap

10 cm

Maximum tensile strength longitudinal / transverse

220 / 220 N/5 cm

EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner

Elongation longitudinal / transverse

25 / 25 %

EN 12 311-2, without support liner EN 13 859-1, Appendix A, with support liner

Resistance to tearing (nail) longitudinal / transverse

230 / 210 N

EN 12 310-1 without support liner EN 13 859-1, Appendix B, with support liner
Air tightness air tight

Minimum roof slope

5° (Zusatzmaßnahme bei Dachneigungen zwischen 5° und 9°: Verklebung der Überlappung (15 cm) mit Ampacoll Superfix (Dichtfunktion) und Überklebung der Überlappung mit Ampacoll XT 60 mm (mechanische Sicherung)
Visible defects none EN 1850-2
Values after artificial ageing

Water vapour permeability, sD value

approved EN 1296, 70°C / EN 1931
Technical data sheets
pdf Technical data sheet: Ampatex SB 130 (plus) Technical data sheet: Ampatex SB 130 (plus), formwork membrane and airtight layer
Declarations of performance
pdf Declaration of performance: Ampatex SB 130 Declaration of performance: Ampatex SB 130 1.5 x 100 m, formwork membrane and airtight layer
pdf Declaration of performance: Ampatex SB 130 Declaration of performance: Ampatex SB 130 3.0 x 50 m, formwork membrane and airtight layer
Tendering texts
pdf Tendering text: Ampatex SB 130 Tendering text: Ampatex SB 130, formwork membrane and airtight layer
Product inserts
pdf Product insert: Ampatex SB 130 Product insert: Ampatex SB 130 1.5 x 100 m, formwork membrane and airtight layer
pdf Product insert: Ampatex SB 130 Product insert: Ampatex SB 130 3.0 x 50 m, formwork membrane and airtight layer
Product photos
jpg Product photo: Ampatex SB 130 Product photo: Ampatex SB 130, formwork membrane and airtight layer
Application photos
jpg Application photo: Ampatex SB 130 Application photo: Ampatex SB 130, formwork membrane and airtight layer
jpg Application photo: Ampatex SB 130 Application photo: Ampatex SB 130, formwork membrane and airtight layer
jpg Application photo: Ampatex SB 130 Application photo: Ampatex SB 130, formwork membrane and airtight layer

Ampatex SB 130 is a weather-resistant vapor check and airtight layer in one. All joints, gaps, overlaps, connections and  openings must be made airtight. Any damage to the surface must be sealed. Ampatex SB 130 is usually used on the warm  side of the insulation. The membrane runs parallel to the eaves on the existing two-dimensional substructure and the overlaps (10 cm) are fastened with concealed nails. The overlaps are glued with Ampacoll XT. Flashing on chimneys, skylights, etc.,  must be bonded with Ampacoll BK 530, 20 mm at least 15 cm high. Penetrations such as outlet vents, chimneys, etc.,  should be taped with Ampacoll BK 535 butyl rubber tape, 50 or 80 mm, to make them airtight and rainproof. Porous, dusty  or rough surfaces should be pretreated with Ampacoll Primax or Airmax.

Back to overview